Models 6700, 6705 & 6715 Scanning Spectrophotometers
Request literature on this product via mail
67 Series Demo Video
Application Notes

  • Color (TFT) LCD with touch-screen interface
  • Sealed QWheelTM control
  • Removable SD & SD/USB memory card
  • Plug-in accessory modules
  • Secure multi-user operation
  • PC software included

Model 6700 covers the visible wavelength range with a spectral bandwidth of 4nm.
Model 6705
covers the UV/visible wavelength range with a spectral bandwidth of 4nm.
Model 6715
meets the EP/USP requirements with a spectral bandwidth of 1.5nm across the UV/visible wavelength range.

The large, color touch-screen display ensures the fastest response to operator input and the clearest presentation of options and results. A sealed QWheelTM is provided for fine cursor control or scrolling. With this cutting-edge user interface and novel operating system the 67 series offer the simplest, most intuitive operation in their class. Secure multi-user operation can be selected where each users settings, methods and results are protected by PIN codes. A designated supervisor can control user access and back up data and settings. Open, free use is always available at any time without logging in to the protected areas. For extra security stored information can be held on a removable memory card.

All data, methods and settings can be transferred to another instrument or PC using the removable SD/USB memory card. Multiple instruments are easily formatted with identical settings, while the latest methods can always be uploaded from the memory cards.

The PC software included enables the easy transfer of data and methods from the instrument or SD memory card to the computer for printing, storage, presentation or further manipulation.

The removable sample chamber enables a number of plug-in accessory modules to be fitted, making the rapid configuration (and reconfiguration) of the desired sampling options possible. Accessory modules include an eight cell auto changer, a sipper pump for flow-through cuvettes, a peltier temperature controlled cuvette holder and peltier/sipper system, as well as single 10mm cuvette, long path length and test tube holders.

The 67 series offer the following modes of operation
Photometrics
for simple Absorbance and %T measurements at selected wavelengths.
Kinetics
for timed measurement and enzyme reaction monitoring.
Quantitation
for concentration measurements based on calibration with 1 to 20 standards.
Multi-Wavelength
measurements with calculations based on up to 4 discrete wavelengths.
Scanning
at an impressive 1500nm/minute, even with data collection at 0.1nm intervals. This enables zooming to higher resolutions without the need to re-scan and full post scan re-scaling of either axis.

*QWheel is a trade mark of Quantum Technology Group.

Specification
  Light Source   Tungsten Halogen (6700) and  Xenon (6705/6715)
  Optics  Sealed, MgF coated, split beam
  Wavelength range 320-1100nm (6700) 190-1100nm (6705/6715)
  Wavelength resolution 0.1nm
  Wavelength accuracy ±1.0nm
  Wavelength repeatability  ±0.2nm
  Spectral Bandwidth 4nm (6700/6705) 1.5nm (6715)
  Stray Light <0.1 at 340nm (6700) <0.05 at 220nm (6705/6715)
  Photometric ranges -0.300 to 3.000A & 0 to 199.9%T
  Photometric resolution 0.001A & 0.1%T
  Photometric accuracy ±0.005 at 1A
  Photometric stability <0.001A per hour
  Quantitation range -99999 to +99999
  Number of Standards 20 with up to 5 replicates of each
  Curve Fit Algorithms Linear, Quadratic and Cubic functions
  Multi-Wavelength Data Points Up to 4 wavelengths
  Calculations Difference and ratio
  Kinetics time limits 0 to 9999 seconds
  Kinetics calibration   Standard or Factor
  Scan speed 1500nm/minute at 0.1nm data steps
  Post Scan analysis Peak/Valley pick, Peak Ratios, Area, Zoom, Wavelength Table, Derivatives, Smoothing
  Configuration Secure multi-user and Free Access 
  Number of Users  10 + Supervisor    
  Number of Methods >1000 (on internal flash memory or removable media)
  Results Storage >1000 (on internal flash memory or removable media)
  Removable Media MM/SD memory card or SD/USB memory card
  Interface USB, Centronics, Analogue
  PC Software Supplied on CD-ROM with USB interface cable
  Mains supply 100 to 230V ac / 50 or 60Hz
  Sample compartment   150mm (max. height) x 130mm (w) x 210mm (d)
  Size 490 x 390 x 220mm
  Weight 20 lbs

Ordering Information
  6700 Model 6700 visible range, 4nmSBW Single Beam spectrophotometer fitted with single 10 x 10 mm cuvette holder, internal thermal 40-column printer, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, US/UK/EU power cable, PC software on CD ROM with interface cable.
Configuration: 670-A-E-1-5-3-01-1-0-01-1
  6705 Model 6705 UV/Visible range, 4nm SBW, Split Beam spectrophotometer fitted with single 10 x 10 mm cuvette holder, internal thermal 40-column printer, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, US/UK/EU power cable, PC software on CD ROM with interface cable.
Configuration: 675-A-E-1-5-3-01-1-0-17-1
  6715 Model 6715 UV/Visible range, 1.5nm SBW, Split Beam spectrophotometer fitted with single 10 x 10 mm cuvette holder, internal thermal 40-column printer, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, US/UK/EU power cable, PC software on CD ROM with interface cable.
Configuration: 671-A-E-1-5-3-01-1-0-17-1
  6715-8 Model 6715 UV/Visible range, 1.5nm SBW, Split Beam spectrophotometer fitted with an automated eight-position cuvette holder, internal thermal 40-column printer, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, US/UK/EU power cables, PC software on CD ROM with interface cable. Configuration: 671-A-E-1-5-3-02-1-0-17-1

 


Accessories

External Memory Cards (removable media)
019 130
256MB SD card
019 131
512MB SD card
019 132 1GB SD card
019 133 2GB SD card
019 135 1GB SD/USB
019 136 2GB SD/USB

Interchangeable Sample Handling Modules

660 802 Single cell module with 10x10mm cuvette holder (630 204*)  
660 402 Automatic 8 cell changer module click for a larger picture
660 502 Water heated automatic 6 cell changer module  
660 202 Sipper module click for a larger picture
660 302 Peltier module click for a larger picture

660 702 Sipper/Peltier module
660 902 Single cell module with 10mm cuvette/16 and 24mm dia. tube holder (637 071*)
661 002 Single cell module with 10x100mm cuvette holder (630 005*)
661 102
Single cell module with micro cuvette holder with reduced aperture (630 304)
661 202
Single cell module with water heated cuvette holder (648 001*

Sample holders that may be fitted in any single cell modules marked *
630 204
10mm path length cuvette holder
637 701
Cell holder for 10mm square cuvettes, 16 and 24mm dia. tubes
630 005 10 to 100mm path length cuvette holder
630 304
Micro cuvette holder with reduced aperture
648 001
Water heated single cuvette holder

Additional carousels for high-throughput and heavy workloads
660 403
Additional carousel for automatic 8 cell changer (for use with 660 402)
660 503
Additional carousel for water heated automatic 6 cell changer (for use with 660 502)

Additional Accessories
660 001
Dust Cover
060 422 Moulded rack for 16 10x10mm cuvettes
035 088 Visible Calibration Set

Spares
037 702
Paper roll for thermal printer
012 075
Tungsten halogen lamp module
012 146
Xenon lamp module

Home | Spectroscopy Products | Online Store | News
 Application Notes | Contact Us | About Us
Copyright © 2008 Techne® Incorporated