Photometric measurements in Absorbance and Transmittance
-
Concentration measurement by direct factor entry or against blank and
standard
-
Quantitation using up to 6 standards - with curve correction and
correlation coefficient
-
Kinetics with real time graphical display of sample and standard runs
-
Spectrum - scanning any range from 320-1000nm
-
Store
up to 50 methods in each mode
-
Includes free 63Ten PC software
|
 |
|
An advanced measuring
system with modes for Photometrics, Concentration, Quantitation, Kinetics
and Scanning. The 6310 will meet the demands of a wide range of
applications, especially those in the clinical, veterinary, environmental,
general QC and performance testing areas.
|
Features
include:
With a memory capacity of 50
methods for each mode, the fully open operating system ensures compatibility
with reagent kits from most manufacturers, as well as enabling full
customization to the operator's choice of
chemistries and operating procedures.
Simple keypad
layout and novel customizable menus ensure reliable operation by
unfamiliar users.
Supervisor
Security functions, when activated, enable all the set up options to be
locked. These cannot be
changed without the entry of a security code number.
Simultaneous
display of Absorbance, Transmission and Wavelength in the
Photometrics mode means that
manual range changing is not necessary.
Simple
concentration measurements using a single standard or factor can be made
in the concentration
mode. The Quantitation mode allows more complex
concentration
methods to be programmed, using up
to 6 standards to create a calibration curve.
For
each curve fit option a linearity correlation coefficient
is calculated.
A real-time
graphical display of Kinetic measurement is shown, along with the
calculated concentration
value and other relevant data.
The Spectrum
Scanning mode allows scans to be made across and selected portion
of the 320-1000nm
range. The auto-ranging Absorbance axis allows scans to be
commenced with no prior knowledge of
the peak Absorbance level expected.
The 6310 has an
analogue output that can be used to drive chart recorders and
other analogue recording
or conversion devices.
A
bi-directional RS232 serial port allows connection to serial printers and
computers.
The
63Ten software allows full emulation of the instrument functions on
a PC, including the
importing of results and download of methods. The results can be printed out to
any attached windows printer.
An electrically
heated cuvette holder and control unit is available, as well as a water
heated cuvette
holder and a thermostatically controlled water circulator. The
external,programmable sipper pump
ensures faster and safer sample handling.
The large
sample compartment enables a wide range of sampling devices to be fitted.
Cuvette holders
from 10 to 100mm in path length, a 4 position rotary cuvette
holder and test tubes from 12.5 to 25mm
can all be accommodated.
|
Model 6310 - Specifications |
|
Optics |
Single beam |
|
Wavelength range |
320-1000nm |
|
Resolution |
1nm |
|
Accuracy |
±2nm |
|
Bandwidth |
8nm |
|
Transmittance range |
0 to 199.9% |
|
Resolution |
0.1% |
|
Accuracy |
±1%T |
|
Absorbance range |
-0.300 to
1.999A |
|
Resolution |
0.001A |
|
Concentration range |
-300 to 1999 |
|
Selectable resolution |
1/0.1/0.01/0.001 |
|
Calibration |
Blank with a
single standard or factor |
|
Memory |
50 methods |
|
Quantitation |
-300 to
1999Conc |
|
Selectable resolution |
1/0.1/0.01/0.001 |
|
Calibration |
Blank with
up to 6 standards |
|
Curve
Correction |
Linear
regression, interpolation or linear regression through zero |
|
Memory |
50 methods |
|
Kinetics |
Graphical
and calculated concentration value |
|
Calibration |
Against
standard and factor |
|
Correlation factor |
r squared
value displayed with result |
|
Memory |
50 methods
and 5 graphed results |
|
Spectrum |
Any range
between 320 and 1000nm |
|
Scan data
interval |
1, 2 or 5nm
selectable |
|
Analysis |
Absorbance
and wavelength of peaks and valleys |
|
Memory |
50 methods
and 5 scans |
|
GLP |
Real time
clock and calendar
Operator ID
Supervisor security (locks all set up parameters)
Method display lock |
|
Photometric noise levels |
<1% |
|
Photometric stability |
Better than
1%/hr |
|
Readout |
Custom LCD |
|
Outputs |
Analogue /
RS232 serial port |
|
Input
voltage |
115/230V a.c.
-20% +10% 50/60Hz |
|
Input
power |
<50W |
|
Size (inches) |
14 x 11 x 6 |
|
Weight |
6Kg |
|
631 001 |
Model 6310
Visible range scanning spectrophotometer (320-1000nm) supplied with mains
lead, pack 100 disposable cuvettes, 10x10mm cell holder, 63Ten Software
package and instruction
manual. For use on 230V/50Hz |
|
631 031 |
Model 6310
Visible range scanning spectrophotometer (320-1000nm) supplied with US
line cord, pack 100 disposable cuvettes, 10x10mm cell holder , 63Ten
Software package and
instruction manual. For use on 110V/60Hz |
| 633
001 Heated cuvette system (cuvette holder and external control unit)
supplied with interconnection cables, mains cables for EU, UK and USA and
instruction manual. (Universal voltage and frequency) |
| 632
001 External
Sipper Pump
supplied with inlet and outlet tubing, mains
cable and instruction manual (230V/50Hz) |
| 632
031 External
Sipper Pump supplied with inlet and outlet tubing, mains
cable and instruction manual (110V/60Hz) |
| 630
005 Adjustable path length cuvette holder (10-100mm) |
| 630
204 10mm cuvette holder (supplied as standard with product) |
| 630
020 Test tube holder (13mm diameter) |
| 630
021 Test tube holder (25mm diameter) |
| 630
022 Test tube block (16mm diameter) |
| 634
001 4 position rotary cuvette holder |
| 648
001 Water heated cuvette holder |
| 037
201 Thermostatted water circulator 230V |
| 037
202 Thermostatted water circulator 110V |
|
7062828
Spectrophotometer Printer |
|
543 501 Portable
Thermal Printer |
| 060
287 Paper roll for printer |
| 060
288 Printer ribbon |
| 542
009 Interface cable kit |
| 021
041 DC/AC power converter - enables the product to be powered from a
12v DC supply |
| 630
028 Dust cover |
| 035
088 Calibration set |
| 033
290 Storage case |
|
7062828 Spectrophotometer
Printer supplied with cable |
Glass Cuvettes
Please click here to
view images
|
Jenway Cat. # |
Quantity |
Footprint (mm) |
UV/visible |
Material |
Volume |
Masked or
non-masked |
Wavelength (nm) |
Path Length (mm) |
Path Height (mm) |
|
Glass Cuvettes |
|
|
035-123 |
1/pk |
10x10 |
Visible |
Glass |
500ul |
non-masked |
320-2500 |
10 |
15 |
|
035-126 |
1/pk |
10x10 |
Visible |
Glass |
1ml |
non-masked |
320-2500 |
10 |
15 |
|
035-027 |
1/pk |
10x10 |
Visible |
Glass |
3ml-4.5ml |
non-masked |
320-2500 |
10 |
15 |
|
035-086 |
1/pk |
20x10 |
Visible |
Glass |
7ml |
non-masked |
320-2500 |
20 |
15 |
|
035-029 |
1/pk |
40x10 |
Visible |
Glass |
12-18ml |
non-masked |
320-2500 |
40 |
15 |
|
035-087 |
1/pk |
50x10 |
Visible |
Glass |
17.5ml |
non-masked |
320-2500 |
50 |
15 |
|
035-079 |
1/pk |
100x10 |
Visible |
Glass |
35ml |
non-masked |
320-2500 |
100 |
15 |
|
Glass Flow Cells |
|
|
035-025 |
1/pk |
10x10 |
Visible |
Glass |
1.8ml |
non masked |
320-2500 |
10 |
15 |
|
035-045 |
1/pk |
10x10 |
Visible |
Glass |
80ul |
non-masked |
320-2500 |
10 |
15 |
Quartz Cuvettes
Please click here
to view images
|
Jenway Cat. # |
Quantity |
Footprint (mm) |
UV/visible |
Material |
Volume |
Masked or
non-masked |
Wavelength (nm) |
Path Length (mm) |
Path Height (mm) |
|
Quartz Cuvettes |
|
|
035-124 |
1/pk |
10x10 |
UV-Visible |
Quartz |
50ul |
Masked |
200-2500 |
10 |
15 |
|
035-138 |
1/pk |
10x10 |
UV-Visible |
Quartz |
100ul |
Masked |
200-2500 |
10 |
15 |
|
035-139 |
1/pk |
10x10 |
UV-Visible |
Quartz |
200ul |
Masked |
200-2500 |
10 |
15 |
|
035-125 |
1/pk |
10x10 |
UV-Visible |
Quartz |
500ul |
non-masked |
200-2500 |
10 |
15 |
|
035-127 |
1/pk |
10x10 |
UV-Visible |
Quartz |
1ml |
non-masked |
200-2500 |
10 |
15 |
|
035-028 |
1/pk |
10x10 |
UV-Visible |
Quartz |
3.5ml |
Masked |
170-2700 |
10 |
15 |
|
Quartz Flow Cells |
|
|
035-044 |
1/pk |
10x10 |
UV-Visible |
Quartz |
1.8ml |
non-masked |
190-2700 |
10 |
15 |
|
035-047 |
1/pk |
10x10 |
UV-Visible |
Quartz |
80ul |
masked |
200-2500 |
10 |
15 |
Plastic Disposable Cuvettes and glass
test tubes
|
Jenway Cat. # |
Quantity |
Footprint (mm) |
DNase and RNase free |
UV/visible |
Material |
Volume |
Masked or
non-masked |
Wavelength (nm) |
Path Length (mm) |
Path Height (mm) |
|
Plastic Disposable Cuvettes |
|
|
7062810 |
100/pk |
10x10 |
- |
UV-Visible |
Plastic |
70ul |
non-masked |
220-900 |
10 |
15 |
|
7062812 |
100/pk |
10x10 |
Yes |
UV-Visible |
Plastic |
70ul |
non masked |
220-900 |
10 |
15 |
|
060-087 |
100/pk |
10x10 |
- |
Visible |
Plastic |
1.5-3ml |
non-masked |
340-900 |
10 |
15 |
|
035-132 |
100/pk |
10x10 |
- |
UV-Visible |
Plastic |
1.5-3ml |
non-masked |
200-900 |
10 |
15 |
|
060-231 |
100/pk |
10x10 |
- |
UV-Visible |
Plastic |
1.6ml |
non-masked |
200-900 |
10 |
15 |
|
060-084 |
100/pk |
10x10 |
- |
Visible |
Plastic |
2.4-4.5ml |
non-masked |
340-900 |
10 |
15 |
|
060-229 |
500/pk |
10x10 |
- |
Visible |
Plastic |
2.4-4.5ml |
non-masked |
340-900 |
10 |
15 |
|
060-230 |
100/pk |
10x10 |
- |
UV-Visible |
Plastic |
2.4-4.5ml |
non-masked |
280-1100 |
10 |
15 |
|
060-232 |
500/pk |
10x10 |
- |
UV-Visible |
Plastic |
2.4-4.5ml |
non-masked |
280-1100 |
10 |
15 |
|
035-078 |
100/pk |
100x10 |
- |
Visible |
Plastic |
35ml |
non-masked |
340-900 |
100 |
15 |
|
Disposable test tubes |
|
|
|
|
|
|
|
|
|
060-179 |
100/pk |
12x75 |
- |
Visible |
Plastic |
5ml |
non-masked |
340-900 |
|
15 |
|
060-331 |
100/pk |
12x75 |
- |
Visible |
Glass |
5ml |
non-masked |
340-900 |
|
15 |
|
060-335 |
50/pk |
24x150 |
- |
Visible |
Glass |
40ml |
non-masked |
340-900 |
|
15 |

Home | Spectroscopy
Products | Online
Store | News
Application Notes |
Contact Us | About
Us
Copyright © 2008 Techne® Incorporated |