Combination pH Electrodes
Waterproof pH Electrodes for Models 3150 and 3205 only
Application Specific Electrodes
Separate pH and Reference Electrodes
pH Consumables
Electrode Selection Chart

Combination pH Electrodes - BNC connection.
Not for use with Premier models 3150 & 3205 and Enterprise model 430

click for a larger picture
 

924 001 General purpose, epoxy bodied
Standard measurements of general solutions

click for a larger picture
 

924 002 12mm stem spear type, glass bodied
Measurement of soil and slurry samples

click for a larger picture
 

924 003 Redox (platinum), glass bodied
Redox measurements

click for a larger picture
 

924 004 Micro, 4.5mm diameter, glass bodied
Measurements of liquids in small test tubes and eppendorf vessels

click for a larger picture
 

924 005 General purpose, glass bodied
Standard measurements of general solutions

click for a larger picture
 

924 006 12mm flat head-surface, epoxy bodied
Measurements of paper and surfaces

click for a larger picture
 

924 007 4.5mm semi-micro, 90mm reach, glass bodied
Small volume liquid samples

click for a larger picture
 

924 010 Spear type, 6mm stem, glass bodied
Small volume soil and slurry samples

click for a larger picture

924 030 Tris Buffer, 90mm reach, glass bodied
pH measurement in blood and protein

click for a larger picture
 

924 047 3 in 1 pH/temperature, epoxy bodied

Note Order Code 924 070 should be used for products 3505, 3510 and 3520.

click for a larger picture
 

924 049 Life Science, 6mm micro, 150mm reach, glass bodied
For test tubes with small amounts of sample

click for a larger picture
 

924 050 Environmental, glass bodied
Suitable for low ionic strength solution and waters

click for a larger picture
 

924 051 Food, epoxy bodied
Ideal for measurements of food extracts

Waterproof Versions
For use with Premier range Models 3150 and 3205 only.

click for a larger picture
 

924 052
Waterproof Environmental with ATC

click for a larger picture
 

924 053
Waterproof 12mm stem spear type with ATC

click for a larger picture
 

924 054
Waterproof Redox (platinum) with ATC

click for a larger picture
 

924 055
Waterproof Tris Buffer with ATC

click for a larger picture
 

924 056
Waterproof Food electrode with ATC

Application Specific Electrodes - BNC connection

  Food Electrode
Ideal for measurement of food extracts. Reduced blockage from fat proteins. Perfect for measurements in agar media. Long Lifetime and easy to clean
924 051
(standard) 924 056 (waterproof version - for use with Premier models 3150 and 3205 only)
  Environmental Electrode
Used for low ionic strength solution. Perfect for deionised water. Increased stability. ATC to 4°C
924 050 (standard) 924 052 (waterproof version - for use with Premier models 3150 and 3205 only)
  Life Science Electrode
Used in test tubes with small amount of sample (60µl). Protein resistant junction. Allows immersion into reaction vessels. Temperature range up to 80°C
924 049 (standard only)
  Tris Buffer Electrode
924 030 (standard) 924 055 (waterproof version - for use with Premier models 3150 and 3205 only)
 

Separate pH and Reference Electrodes

  924 015 Glass pH, requires a separate reference electrode
  924 016 Sealed cap calomel reference electrode
  924 017 Double junction reference electrode
  924 036 Ag/AgCl reference electrode (100°C)
 

pH Consumables

  025 179 pH 4 buffer sachets (pack of 10)
  025 180 pH 7 buffer sachets (pack of 10)
  025 181 pH 10 buffer sachets (pack of 10)
  025 037 pH 4 colored buffer solution (red)(500ml)
  025 038 pH 7 colored buffer solution (yellow)(500ml)
  025 039 pH 10 colored buffer solution (blue)(500ml)
  025 162 pH 9.22 buffer solution (500ml)
  025 163 pH 2 buffer solution (500ml)
  025 160 3M KCl electrode fill solution (pH)
  025 161 Electrode cleaning solution (pH)
  025 157 Redox standard (200mV)(500ml)
  025 158 Redox standard (300mV)(500ml)
  025 159 Redox standard (465mV)(500ml)
 
Electrode Application Selection Chart

Catalog number>>>

924-005

924-008

924-007

924-001

924-030

924-006

924-002

924-010

924-015*

027-227

Sample Type                    

Agar

 

 

 

 

 

J

 

 

 

 

Alkaline (High)

 

 

 

 

 

 

 

 

 

 

Beer

J

J

J

J

 

J

 

 

J

J

Blood Product

J

J

J

 

 

J

 

 

J

 

Bread, Dough

 

 

 

 

 

 

J

J

 

 

Cement

J

 

 

 

 

 

 

 

 

 

Cosmetics

J

J

J

J

 

J

 

 

 

 

Dairy Products

J

J

J

 

 

J

 

J

 

 

Education

J

 

 

J

 

J

 

 

J

J

Fats/Creams

 

 

 

 

 

 

 

J

 

 

Field Use

 

 

 

J

 

J

J

 

 

J

Fish Product

 

 

 

 

 

J

 

J

 

 

Lab Flasks

 

J

 

 

 

 

 

 

 

 

Low Ionic

J

 

 

 

 

 

 

 

 

 

Meat, Cheese

 

 

 

 

 

J

 

J

 

 

Micro Samples

 

 

J

 

 

 

 

 

 

 

Paint

 

J

J

 

 

J

 

 

J

 

Photographic

 

 

 

 

 

 

 

 

 

 

Soil

 

 

 

 

 

 

J

J

 

 

Surface

 

 

 

 

 

J

 

 

 

 

Test Tubes

 

J

 

 

J

 

 

 

 

 

Tris Buffer

 

 

 

 

J

 

 

 

 

 

Viscose samples

 

 

 

 

 

J

 

 

 

 

J Recommended for this Sample Type

*Requires separate reference electrode.

Note: For emulsions, liquors, non-aqueous samples and oils please consult your dealer.
         For Hydrofluoric acid samples use type 924-046

Home | Electrochemistry Products | Online Store | News