The TC412 is a high performance, high sample throughput instrument at a highly affordable price. Flexible block format: The truly user-friendly fully interchangeable block system allows blocks to be exchanged in a matter of seconds, without the need of any tools (60 x 0.5ml, 96 x 0.2ml, for either half skirted or non skirted plates, 384-well or flat plate for in-situ). New design flexible heated lid: Defined pressure, programmable heated lid to accommodate a variety of consumables. Intuitive programming: The 4-line display with intuitive, simple-to-use software with alphanumeric programming, password protection, simple copy/edit functions and much more. 8 Peltiers: Building on the innovative Quad Circuit Technology of the TC512, the TC412 ensures unsurpassed control accuracy and temperature uniformity.
Low cost: The
TC412 is probably the most affordable full sized Thermal
Cycler. |
![]() ![]() |
![]()
|
TCQ412 Quad Thermal cycler Package
Unbeatable
value
|
![]() |
|
Specifications
|
|
|
Blocks Formats
|
|
| 0.5ml capacity | 60 |
| 0.2ml capacity | 96 |
| 384-well block | Yes |
| In-situ block | Yes |
| User interchangeable | Yes |
|
Block Temperature Specifications
|
|
| Maximum ramp rate* | 2.6°C/sec |
| Block uniformity at 50°C* | <ą0.3°C |
| Temperature range | 4°C to 99°C |
| Temperature set point precision | 0.1°C |
| Heated Lid | |
| Selectable heated lid temperature | 100°C - 115°C |
| Heated lid enable/disable | Yes |
| Over temperature cut out | Yes |
| Regulated lid pressure | Yes |
| Heated lid only comes on if block is set above 35°C | |
| Programming | |
| Number of programs # | 80 |
| Password protection | Yes |
| Programming | 4-line alphaN |
| Graphical display | No |
| Incremental/decremental temperature | Yes |
| Incremental/decremental hold time | Yes |
| Maximum hold time | 18 hrs |
| Minimum hold time | 1 sec |
| Variable programmable ramp rate | 0.1°C/sec steps |
| Run end time calculation | Yes |
| Pause and stop facility | Yes |
| End of program alarm (enable/disable) | Yes |
| Auto restart on power failure | Yes |
| Miscellaneous | |
| Serial port | RS232 |
| Dual Voltage (120/230V) | Yes |
| Temperature sensor | Thermistor |
| Peltierelements/block | 8 |
| Dimensions L x W x H (in inches) | 16.5 x 8.6 x 10.2 |
| Footprint L x W (in inches) | 142 in2 |
| Connection to PC control program | Yes |
| Free software upgrades from website | Yes |
| Power consumption | 620 Watts |
| Frequency | 50 - 60 Hz |
|
Net weight |
11kg (total) |
|
Warranty |
4 years or 80,000 cycles-parts and labor |
|
* Given are typical values of a standard 0.2ml block,
in an ambient temperature of 20°C. |
|
|
Ordering Information |
||
| Catalog Number | Description | Voltage |
| FTC41H2D | TC-412 96 x 0.2mL microtubes or 96-well plate (half or no skirt) | 120/230 |
| FTC41S5D | TC-412 60 x 0.5mL microtubes | 120/230 |
| FTC4384D** | TC-412 384-well microtitre plate | 120/230 |
| FTC41FLD** | TC-412 Flat Plate for in-situ | 120/230 |
| FTC4QH2D | TCQ-412 96 X 0.2mL microtubes or 96 well plates (includes 4 Thermal cyclers and all accessories required to connect units to each other) | 120/230 |
|
FTC4Q38D**
|
TCQ-412 384-well microtitre plate (includes 4 Thermal cyclers and all accessories required to connect units to each other) | 120/230 |
| Accessories | ||
| FTC41BHD | Block for 96 x 0.2mL microtubes or 96-well plate (Half or no skirt) | Block |
| FTC41B5D | Block 60 x 0.5mL microtubes | Block |
| FTC4B384** | Block for 384-well microtitre plate | Block |
| FTC41BID** | Flate plate block for in-situ | Block |
| 7022740 |
Aluminum
PCR sealing Film, non sterile - 100 pack - $71.40 (Compare our price to others) |
|
| 7022741 |
Aluminum
PCR sealing Film, Sterile - 50 pack - $45.82 (Compare our price to others) |
|
| 7022556 | Gensoft software for 1-5
units free from website Click here to download |
Software |
| 7022563 | Gensoft software for 6-32 units. Please contact TechneŽ | Software |
| Thermal Cycler tubes and accessories | ||
|
The
items below are required to connect multiple TC412's to your PC to create a thermal cycler network. (Note: These are included in the TCQ-412 system above.) |
||
| 7022558 | Terminator | 120 volt |
| 7022557 | Terminator | 240 volt |
| 7022559 | One cycler cable extension kit | cable kit |
| 7022560 | Two cycler cable kit | cable kit |
| 7022690 | Four cycler cable kit | cable kit |
| 7022562 | Ten cycler cable kit | cable kit |
|
** Available by special order only |
||
Technical
notes:
(REF FGEN-01)![]()
Block temperatures
To provide thermal cyclers with the high performance and specificity required
for the protocols of today, heated block design and program versatility are
important features.
Incremental/decremental
temperatures
Touchdown DNA protocols are where a higher temperature is required for the
initial cycles than later cycles. This ensures that only highly specific product
is created (amplified) during the critical initial steps. A decreased, less
stringent temperature is then used by gradually decreasing the annealing
temperature. The effect is a higher yield and more specific product. Therefore,
to eliminate the need for programming lengthy error prone protocols, choose a
thermal cycler which can automatically incorporate an incremental
decrease/increase in temperature.
Incremental/decremental
time
Long template DNA is the amplification of large fragments of DNA (e.g. 40kb
lambda, 27kb Genomic). To ensure that the extension is fully complete after each
cycle, the extension time is increased with each cycle to compensate for the
increased product quantity and decreasing concentrations of reagents. As above
with temperature, choose a thermal cycler which can automatically
increase/decrease hold time at a given temperature.
Peltier
technology
The peltier effect is used in many applications for the reliable cooling of
sensitive high-temperature components without the need for refrigerants or
compressors. Otherwise known as thermoelectric coolers, peltiers are a special
type of semiconductor that function as a solid state heat pump. By applying a
low voltage DC power source to one side, heat will be moved in the direction of
the current (+ to - ). The heat is thus pumped from one side of the module to
the other, so that one face will be cold while the opposite face will be heated.
As this effect is reversible, peltier technology is the chosen method for
heating and cooling the block in the best thermal cyclers on the market today.