Dri-Block Heaters
Request literature on this product via mail
Download the DB2A Dri-block manual (538kb pdf)
Download the DB2D & DB3D Dri-block manual (376kb pdf)
Download the DB3A Dri-block manual (336kb pdf)

Sample Concentrator
Ask about our Trade-in Program

Techne® Dri-Block® heaters are the economical answer to every laboratory's need for a compact constant temperature heater suitable for test tubes, cuvettes, micro-centrifuge tubes, 96 well plates and other small containers. Dri-Blocks are particularly suitable for microbiology and clinical laboratories for incubation, boiling, inactivation, wet ashing, sample concentration, enzyme analysis and other general uses. They are also used for a variety of industrial applications. The heat transfer medium is an aluminum alloy block with machined cavities to accept test tubes or sample containers.

CONSTRUCTION

Dri-Block ® heater units have a recessed chamber to hold up to two interchangeable insert blocks (in the DB-2A, DB-2D - or one aluminum insert block and two plastic spacers). Three in the DB-3, DB-3A and DB-3D. The blocks are made of an aluminum alloy with excellent thermal conductivity and are drilled with a choice of different hole sizes for tubes and containers ranging from 6mm to 26mm diameter.

Other blocks are available, including three for 0.5ml, 1.5ml or 2.0ml micro-centrifuge tubes and two alternative sizes undrilled for customers who wish to machine their own requirements. Each aluminum alloy insert block has a threaded thermometer hole which also accepts the insert block extraction tool for ease of removing insert blocks from the heated chamber (not applicable to insert blocks reference F4467, F4468, F4469).

A close fit of the tubes in the block ensures high heat transference to the tube and the heater design, temperature sensor and solid state circuitry give exceptionally good temperature control uniformity.

Temperature setting on the DB-2A, DB-3 and DB-3A is by a dial calibrated in degrees centigrade. Heat up rate on all units is rapid.

Independent lights indicate mains power, heater action and temperature conditions are incorporated and an on/off switch is mounted on the rear panel. The units are strongly constructed, light in weight and have extremely efficient insulation to ensure that the case remains cool enough to handle even at maximum operating temperatures.

SAFETY

The Dri-Block ® range has been designed to deal with all important RF interference and electrical safety regulations.

 

The DB-2A is designed to take up to two aluminum alloy insert blocks. Temperature setting is by a calibrated knob/dial in degrees centigrade. Temperature range ambient +5°C to 100°C.


 

The DB-2D is similar in design to the DB-2A accepting two blocks, but has a red LED display. The temperature is set by using the  set and up/down buttons. The large LED panel displays both the set point and actual values.

The DB-3 is similar in design to the DB-3A but with a temperature range ambient +5°C to 100°C.

The DB-3A is designed to take three aluminium alloy insert blocks. Temperature setting is by a calibrated knob/dial in degrees centigrade. Temperature range ambient +5°C to 200°C.

The DB-3D is similar in design to the DB-3A but has a red LED digital display. The temperature is set by using the  set and up/down buttons. The large LED panel displays both the set point and actual values.  Temperature range ambient +5°C to 200°C.
The new DB-2TC is similar to the DB-2D with an innovative design accommodating two blocks with independent digital temperature controls. Each block can be set at different temperatures - ideal for multiple users or applications where samples have to be transferred between two temperatures very quickly. The temperature is set using the "set" and up/down buttons and is displayed on the LED panel.

Specifications

Spec DB2A DB2D DB3 DB3A DB3D DB2TC
Temperature Range Ambient +5°C -100°C Ambient +5°C -100°C Ambient +5°C -100°C Ambient +5°C -200°C Ambient +5°C -200°C Ambient -100°C
Stability @ 40°C ±0.05 ±0.05 ±0.1 ±0.1 ±0.1 ±0.1
Stability @ 100°C ±0.1 ±0.1 ±0.25 ±0.25 ±0.25 ±0.15
Variation between blocks @ 40°C 0.2 0.2 0.2 0.2 0.2 0.1
Set point accuracy ±2.0 ±1.0 ±2.0 ±2.0 ±1.0 ±1.0
Heat-up time (min.) 30-37°C 8 8 8 8 11 6
Heat-up time (min.) 30-56°C 9 9 12 12 15 14
Heat-up time (min.) 30-max. 12 12 19 30 25 19
Overall size, LxWxH 202x260x105 mm
16"x15"x8"
202x260x105 mm
16"x15"x8"
279x260x105 mm
16"x15"x8"
279x260x105 mm
16"x15"x8"
279x260x105 mm
16"x15"x8"
279x260x105 mm
16"x15"x8"
Shipping Weight lbs. 10 10 13 13 13 13
Warranty 3 year parts and labor

Ordering Information:

Catalog Number Model Voltage
1081500 DB-2A 120
1082000 DB-2D 120
1081400 DB-3 120
1081800 DB-3A 120
1081900 DB-3D 120
  DB-2TC 120
Aluminum Insert blocks
Catalog # Tube size/# of tubes Size (LxWxH) mm
6013501 Plain insert block 95 x 76 x 51
6013502 6mm/30 insert block 95 x 76 x 51
6013503 10mm/20 insert block 95 x 76 x 51
6013504 12mm/20 insert block 95 x 76 x 51
6013505 13mm/20 insert block 95 x 76 x 51
6013506 15mm/12 insert block 95 x 76 x 51
6013507 16mm/12 insert block 95 x 76 x 51
6013508 19mm/8 insert block 95 x 76 x 51
6013509 25mm/6 insert block 95 x 76 x 51
6013510 10mm cuvettes insert block 95 x 76 x 51
6013512 Plain block DB3/DB4 thermometer hole only 95 x 225 x 51
6014460 Plain block with thermometer hole 95 x 76 x 51
6014462 24mm/6 insert block 95 x 76 x 51
6014463 26mm/6 insert block 95 x 76 x 51
6014464 1.5mL EPP/20 insert block 95 x 76 x 51
6014465 0.5mL EPP/30 insert block 95 x 76 x 51
6014466 Set of two plastic insert blocks 95 x 37 x 51
6014467 96 well insert block 95 x 151 x 61
6014468 Falcon Round bottom insert block 95 x 151 x 61
6014469 Falcon Flat insert block 95 x 151 x 61
6014470 2.0mL/20 insert block 95 x 76 x 51
6014471 0.2mL/72 insert block 95 x 76 x 51


Ask about our Trade-in Program
Home | General Lab Products | Online Store | News
Contact Us | About Us
Copyright © 2008 Techne® Incorporated