- Na, K,
Ca, Ba & Li Filters as standard
|
- Operates on Propane, Butane, Natural Gas or LPG supplies
|
|
|
|
- Electronic Flame Failure detection
|
|
- Fine and Coarse Sensitivity controls
|
|
The Techne® Model PFP7/C is a low temperature, single channel Flame
Photometer, designed for the routine determinations of Sodium (Na) and
Potassium (K). Additional filters for the measurement of
Lithium (Li), Barium (Ba) and Calcium (Ca) are
included.
The instrument is fitted with automatic flame failure detection for
user safety, making it ideal for use in clinical, industrial and
educational applications.
The Model PFP7/C is designed specifically for use in Clinical
applications. The in-built linearizer circuitry enables readings of both
Sodium and Potassium, at the normal clinical serum concentrations, to be
directly displayed in mmol/l. Serum samples need to be diluted 200:1 or
100:1 prior to presentation to the flame photometer. To enable this to be
carried out efficiently Jenway are able to offer the Model 8225
Diluter.
There is also a standard version of this instrument, the Model
PFP7.
Model PFP7/C Specifications |
| Ranges |
120 - 160mmol/l Na (linearised) / 0 -10.0mmol/l K |
| Limits of Detection |
Li <=0.25ppm / Ca <=15ppm / Ba <=30ppm |
| Reproducibility |
<=1% / Coefficient of Variation for 20 consecutive samples
using 10ppm Na set to read 50 |
| Linearity |
Better than 2% when concentration of 3ppm Na and K and 5ppm Li
are set to read 100 |
| Specificity |
Interference from Na, K and Li equal in concentration to test
element will be >0.5% |
| Recorder output |
Nominal 1.00V for a reading of 100.0 |
| Services: Electrical |
90-125V or 190-250V @ 50/60Hz |
| Services: Air |
Moisture and oil free 6
liter/minute @ 1Kg/cm2
(14psi) |
| Services: Fuel |
Propane, Butane, Natural Gas or LPG |
| Size |
420 x 360 x 300mm |
| Weight |
8Kgs |
| Warranty |
2
year parts and labor |
|
500-801 |
Model PFP7/C supplied with
Na, K, Ca, Ba & Li
filters, connecting
hoses and clips, compressor plug, drain trap, fuses, mains lead and
combined Instruction/Service manual. 230 volt, 50/60HZ |
|
500-831 |
Model PFP7/C supplied with
Na, K, Ca, Ba & Li
filters, connecting
hoses and clips, compressor plug, drain trap, fuses, mains lead and
combined Instruction/Service manual. 115 volt, 50/60HZ |
A number of additional accessories are available for the Flame
Photometer range, including additional filters /
regulators and a selection of clinical and industrial
standard solutions.

Home | Online
Store | News
Contact Us | About
Us
Copyright © 2008 Techne® Incorporated |