Aquanova Environmental Analyzer

Product Overview
Specifications
Order Codes

Accessories
Request literature on this product via mail
Ask about our Trade-in Program
 

Product Overview

With a simple step-by-step guide to successful measurement, the Jenway Aquanova brings an intelligent and flexible solution to water, waste, and environmental analysis.  Aquanova's impressive software will download or update the latest test methods from the internet or CD-ROM. New methods can be created or customized on the unit or via linked PC.

  • Open system compatible with most available test kits

  • Includes PC software with full instrument emulation.  Drag and drop test methods from the PC or internet

  • Stores up to 300 named methods in memory.  Test kits provided for the pre-loaded methods enable rapid start up.

  • True spectrophotometer with full wavelength range from 320 to 1000nm and Absorbance and %T readout

  • Flexible sample holder fitted as standard with full range of optional sample holders available

  • Integral timer with auto-save on time out

Although dedicated to water and environmental analysis Aquanova can still be used as a standard single beam visible spectrophotometer by selecting the Photometric menu option. Absorbance, %T and wavelength are displayed giving added functionality and flexibility. This will be especially useful in method development, as well as in areas where teaching and training is carried out.

A multi-purpose sample holder that will accept 10mm path length cuvettes as well as 16mm and 24mm diameter sample tubes, is fitted to Aquanova. Where longer path lengths are required the optional 10 to 100mm path length cuvette holder can be fitted. A range of alternative sample holders, cuvettes and tubes are available to enhance the capabilities of Aquanova.



Aquanova Specifications

Wavelength
Range 320 - 1000nm
Resolution 1nm
Accuracy ±2nm
Bandwidth 8nm
Photometric mode Yes-selectable wavelength 195 to1000nM
Absorbance
Range -0.300 to 1.999A
Resolution 0.001A
Transmittance
Range 0 to 199.9%
Resolution 0.1%
Stray Light <0.5% @ 340nm & 220nm
Photometric Accuracy ±1%
Concentration
Range -300 to 1999 units
Resolution 1, 0.1, 0.01, 0.001
Units

mg/l, g/l, blank, %, ppm, pH, mg/kg, IFZ, HZ, MEq, U/ml, mU/l, u/l, µM/l, mM/l, M/l, µg/ml, mg/ml, µg/dl, mg/dl, g/dl, ng/l, µg/l

Light Source

Tungsten halogen

Dimensions 365(w) x 272(d) x 160(h)mm
Weight 13 lbs
Input Voltage 115/230V AC -20% +10% 50/60Hz
Outputs RS232/analog

Ranges

Test Methods Photometric (Abs/%T)

Test Name

Up to 20 alphanumeric characters

Test Memory

300 methods

Results Memory

50 results

Timer

1 second to 24 hours / 1 second resolution / cal or save on time out

Factor

9999.999 to 0.001

Calibration Curve

up to 6 standards

Clock

Time (24 hour) and date

Communication

RS232 - PC application software included. Download tests from PC or website

Warranty 3 years parts and labor (Tungsten halogen lamp not included)

Aquanova Order Codes

637 001 Aquanova spectrophotometer (320-1000nm), 230V supplied with mains lead, 9 way serial cable (013 203), PC Application Software on CD ROM (603 436) and instruction manual.
637 031 Aquanova spectrophotometer (320-1000nm), 115V supplied with mains lead, 9 way serial cable (013 203), PC Application Software on CD ROM (603 436) and instruction manual.

Aquanova Accessories and Test Kits

630 028 Dust Cover
033 290 Storage/Carry case
060 426 16 mm sample tubes (pack 20)
060 425 24 mm sample tubes (pack 24) (24x14.8mm)
060 331 Pack of 100 disposable glass test tube (12x75mm)
060 179 Pack of 100 disposable plastic test tube (12x75mm)
060 335 pack of 50 disposable plastic test tubes (24x150mm)
037 601 Digester for COD determinations, 230V (includes 2 blocks for 12 COD test tubes each)
037 602 Digester for COD determinations, 115V (includes 2 blocks for 12 COD test tubes each)
037 603 Block for 12 COD tubes
637 057 16mm diameter COD tube holder
630 204 10mm path length cuvette holder
630 005 10 to 100mm path length cuvette holder
634 001 4 position cuvette holder
543 501 40 column Portable Printer, 117V
060 287 Paper roll for printer
060 288 Printer ribbon
035 088 Visible calibration set
035 026 Pour in/Suck out cell
025 300 Alkalinity m Test Kit
025 301 Alkalinity p Test Kit
025 302 Aluminum Test Kit
025 303 Ammonia Test Kit
025 304 Ammonium LR  Test Kit
025 305 Ammonium HR Test Kit
025 306 Bromine Test Kit
025 307 Chlorine (Free) Test Kit
025 308 Chlorine (Total) Test Kit
025 309 Chlorine Dioxide Test Kit
025 310 COD (LR) Test Kit
025 311 COD (MR) Test Kit
025 312 COD (HR) Test Kit
025 313 Chromium (Total) Test Kit
025 314 Chromium (Hex) Test Kit
025 315 Copper (Total) Test Kit
025 316 Copper (Free) Test Kit
025 317 Fluoride Test Kit
025 318 Hardness Total Test Kit
025 319 Hazen Color Test Kit
025 320 Hydrogen Peroxide Test Kit
025 321 Iodine Test Kit
025 322 Iron (Soluble) Test Kit
025 323 Manganese Test Kit
025 324 Molybdate Test Kit
025 325 Nitrate Test Kit
025 326 Nitrite Test Kit
025 327 Nitrogen (Total) (LR) Test Kit
025 328 Nitrogen (Total) (HR) Test Kit
025 329 Oxygen Active Test Kit
025 330 Orthophosphate Test Kit
025 331 pH Test Kit
025 332 Potassium Test Kit
025 333 Silica Test Kit
025 334 Sulphate Test Kit
025 335 Sulphide Test Kit
025 336 Sulphite Test Kit
025 337 Zinc Test Kit

Cuvette Ordering Information
Glass Cuvettes             Please click here to view images

Jenway Cat. # Quantity Footprint (mm) UV/visible Material   Volume Masked or
non-masked
Wavelength (nm) Path Length (mm) Path Height (mm)
Glass Cuvettes
035-123 1/pk 10x10 Visible Glass 500ul non-masked 320-2500 10 15
035-126 1/pk 10x10 Visible Glass 1ml non-masked 320-2500 10 15
035-027 1/pk 10x10 Visible Glass 3ml-4.5ml non-masked 320-2500 10 15
035-086 1/pk 20x10 Visible Glass 7ml non-masked 320-2500 20 15
035-029 1/pk 40x10 Visible Glass 12-18ml non-masked 320-2500 40 15
035-087 1/pk 50x10 Visible Glass 17.5ml non-masked 320-2500 50 15
035-079 1/pk 100x10 Visible Glass 35ml non-masked 320-2500 100 15

Quartz Cuvettes    Please click here to view images

Plastic Disposable Cuvettes and glass test tubes

Jenway Cat. # Quantity Footprint (mm) DNase and RNase free UV/visible Material   Volume Masked or
non-masked
Wavelength (nm) Path Length (mm) Path Height (mm)
Plastic Disposable Cuvettes
060-087 100/pk 10x10 - Visible Plastic 1.5-3ml non-masked 340-900 10 15
035-132 100/pk 10x10 - UV-Visible Plastic 1.5-3ml non-masked 200-900 10 15
060-231 100/pk 10x10 - UV-Visible Plastic 1.6ml non-masked 200-900 10 15
060-084 100/pk 10x10 - Visible Plastic 2.4-4.5ml non-masked 340-900 10 15
060-229 500/pk 10x10 - Visible Plastic 2.4-4.5ml non-masked 340-900 10 15
060-230 100/pk 10x10 - UV-Visible Plastic 2.4-4.5ml non-masked 280-1100 10 15
060-232 500/pk 10x10 - UV-Visible Plastic 2.4-4.5ml non-masked 280-1100 10 15
035-078 100/pk 100x10 - Visible Plastic 35ml non-masked 340-900 100 15
Disposable test tubes
060-179 100/pk 12x75 - Visible Plastic 5ml non-masked 340-900 15
060-331 100/pk 12x75 - Visible Glass 5ml non-masked 340-900 15
060-335 50/pk 24x150 - Visible Glass 40ml non-masked 340-900 15

 