Model 4510
Conductivity/TDS Meter |
![]() |
||
|
|
Ideal for routine laboratory applications |
|
|
|
Automatic range selection |
|
|
|
Conductivity/TDS display |
|
|
|
Calibration on
standard solutions or |
|
|
|
Automatic temperature compensation |
|
|
|
32 reading memory |
|
|
|
Back lit custom LCD |
|
|
|
RS232 serial interface and analogue outputs |
|
|
|
Wall mounting option |
|
|
The Model 4510
is a versatile unit which utilizes the best of modern technology to simplify
operation without sacrificing accuracy or reliability. With pushbutton
operation and a customized liquid crystal display, determination of
conductivity and TDS can readily be achieved with the minimum of operator
training. |
![]()
|
Model 4510 Conductivity/TDS Meter Specifications |
|
Conductivity ranges |
0 to 19.99µS, 0 to 199.9µS, 0 to 1999µS, 0 to 19.99mS, 0 to 199.9mS, 0 to 1999mS |
|
Resolution |
0.01µS, 0.1µS, 1µS, 0.01mS, 0.1mS, 1mS* |
|
Accuracy |
±0.5% ±2 digits |
|
TDS ranges |
0 to 19.99mg/l, 0 to 199.9mg/l, 0 to 1999mg/l, 0 to 19.99g/l, 0 to 199.9g/l, 0 to 1999g/l |
|
Resolution |
0.01mg/l, 0.1mg/l, 1mg/l, 0.01g/l, 0.1g/l, 1g/l* |
|
* |
only with cell constant >5 |
|
Accuracy |
±0.5% ±2 digits |
|
Temperature ranges |
-10 to +105°C / 14 to 221°F |
|
Resolution |
0.1°C / 1°F |
|
Accuracy |
±0.5°C / ±1°F |
|
ATC range |
0 to 100°C / 32 to 212°F |
|
Manual Temp. Comp. |
0 to 100°C / 32 to 212°F |
|
Cell constant |
0.010 to 19.999, default 1.000 |
|
Temperature coeff. |
0.00% to 4.00%, default 1.91% |
|
Reference temp. |
18, 20 25°C, default 25°C |
|
EC ratio (cond to TDS factor) |
0.50 to 0.80, default 0.6 |
|
Auto standard recognition |
10µS, 84µS, 1413µS, 12.88mS |
|
Outputs |
Analogue 1mV per digit / RS232 |
|
Display |
Custom back lit LCD |
|
Power |
Power supply 9V a.c. |
|
Size |
250(l) x 210(w) x 55(d) mm |
|
Weight |
850g |
|
Warranty |
2 years parts and labor |
![]()
|
Model 4510 Accessories |
|
060 406 |
Dust cover |
|
037 901 |
Bench stirrer (battery operated) |
|
903 311 |
Extended length electrode rod (recommended for use with the bench stirrer) |
|
903 300 |
Electrode Holder |
|
037 801 |
Interface cable kit |
|
021 030 |
UK 230V power supply |
|
021 031 |
European 230V power supply |
|
021 032 |
US 115V power supply |
|
021 033 |
230V leaded power supply |
|
025 139 |
Calibration standard 10µS |
|
025 164 |
Calibration standard 84µS |
|
025 138 |
Calibration standard 1413µS |
|
025 156 |
Calibration standard 12.88mS |
|
025 165 |
TDS standard |
|
|
To see our range of Conductivity Cells and Consumables, please see here |
|
050 501 |
DataWay Software on CD-ROM includes electrochemistry interface cable (013 203) & spectrophotometer interface cable (013 210) |
![]()
|
Model 4510 Ordering Information |
|
451 001 |
Model 4510 Conductivity/TDS meter supplied with glass conductivity cell with ATC K=1 (027 013), electrode holder, UK power supply, condensed operating instructions and instruction manual |
|
451 101 |
Model 4510 Conductivity/TDS meter supplied with glass conductivity cell with ATC K=1 (027 013), electrode holder, US power supply, condensed operating instructions and instruction manual |
|
451 201 |
Model 4510 Conductivity/TDS meter supplied with glass conductivity cell with ATC K=1 (027 013), electrode holder, European power supply, condensed operating instructions and instruction manual |
|
451 301 |
Model 4510 Conductivity/TDS meter supplied with glass conductivity cell with ATC K=1 (027 013), electrode holder, 230V leaded power supply, condensed operating instructions and instruction manual |
Home |
Electrodes |Products | Online Store |
News
Contact Us | About
Us | Distributors