The Model 3540 Combination
Conductivity / pH Meter
Request literature on this product via mail

|
|
The Model
3540 is ideal for use in water testing applications and in all
laboratories where pH and conductivity analysis is required. It offers a
space saving and flexible approach to the measurement of these two
parameters. The bright back lit LCD has five separate tabbed screens,
each accessed with the simple navigation keys. The set-up menu gives
quick and easy access to the wide range of instrument, pH and
conductivity measurement options. |
The conductivity
channel has a special ultra-pure water function which enables the
temperature compensation algorithm for this exacting application. Other
modes of operation enable Resistivity, Salinity and TDS measurement. The pH
channel can also display mV values to 0.1mV resolution, enabling ORP/Redox
measurements to be made.
The built in
data logger can store up to 250 pH and conductivity readings based on manual
or automatically timed triggers, as well as from stability and alarm status.
Logged results can either be sent to the internal memory or via the RS232
serial port to the optional printer.
A newly launched DataWay
PC software program is useful for data acquisition. Data can be
automatically or manually logged and displayed in both tabular and graphical
form.
The comprehensive GLP functions
include calibration reminders and status tracking, operator and sample ID
management and a supervisor security code for all set-up options.
Calibration of
both the pH and conductivity channels is automatic, with the option to
select 1, 2 or 3 calibration points for each. Automatically recognized pH
buffers conforming to the NIST, DIN and JIS standards can be overridden by
manually entered values, as can the 4 automatically recognized conductivity
standards. An option to calibrate the conductivity channel to a cell
constant is also included for quick and simple conductivity measurements. |

Model 3540 Specifications
|
pH Range |
-2.000 to 20.000pH |
|
Resolution |
0.001 / 0.01 / 0.1pH selectable |
|
Accuracy |
±0.003pH |
|
mV Range (Abs & Rel) |
0 to
±1999.9mV |
|
Resolution |
0.1mV |
|
Accuracy |
±0.2mV |
|
Input impedance |
>1012ohms |
|
Calibration |
1, 2
or 3 point |
|
Auto buffer recognition |
Jenway, NIST, DIN, JIS |
|
Manual buffer recognition |
Any
value entered within the range |
|
Conductivity Range |
Auto
ranging from 0.01µS to 1.999S (19.99S with x10 probe) |
|
Resolution |
0.01µS to 1mS (0.01S with x10 probe) |
|
Accuracy |
±0.5%; ± 2 digits |
|
Calibration |
1, 2
or 3 points |
|
Auto standard recognition |
10µS, 84µS, 1413µS, 12.88mS |
|
Manual standard recognition |
Any
value entered within the range or by cell constant value (K
factor) |
|
Reference temperature |
18,
20 or 25°C |
|
Temperature coefficient |
0
(off) to 4%/°C |
|
Temperature ranges |
-10
to +105°C / 14 to 221°F |
|
Resolution |
0.1°C / 1°F |
|
Accuracy |
±0.5°C / ±1°F |
|
MTC/ATC ranges |
0 to
100°C / 32 to 212°F |
|
Outputs |
RS232 serial, analogue and alarms |
|
Clock |
Time
(24 hour) and date |
|
Memory |
250
readings (pH with conductivity) |
|
Data logging |
Timed, stability and alarm level triggers with output to
internal memory or printer/computer |
|
GLP |
Calibration reminder (1 to 999 hours) / Operator and Sample ID /
Security code protection for set-up |
|
Display |
Back
lit 1/8 VGA LCD |
|
Power |
9Vac
from 230/110V mains adapter |
|
Size |
210x250x55mm |
|
Weight |
850g |
|
Warranty |
2 Years parts and
labor |

|
354 001 |
Model 3540 pH/conductivity meter supplied with glass combination
pH electrode (924 005), glass conductivity probe with ATC K=1
(027 013)electrode holder, ATC probe (027 500), pH 4, 7 and 10
buffer sachets, UK power supply, BNC shorting plug (009
146), and operating instructions |
|
354 101 |
Model 3540 pH/conductivity meter supplied with glass combination
pH electrode (924 005), glass conductivity probe with ATC K=1
(027 013)electrode holder, ATC probe (027 500), pH 4, 7 and 10
buffer sachets, US power supply, BNC shorting plug (009
146), and operating instructions |
|
354 201 |
Model 3540 pH/conductivity meter supplied with glass combination
pH electrode (924 005), glass conductivity probe with ATC K=1
(027 013)electrode holder, ATC probe (027 500), pH 4, 7 and 10
buffer sachets, European power supply, BNC shorting plug
(009 146), and operating instructions |
|
354 301 |
Model 3540 pH/conductivity meter supplied with glass combination
pH electrode (924 005), glass conductivity probe with ATC K=1
(027 013)electrode holder, ATC probe (027 500), pH 4, 7 and 10
buffer sachets, 230V leaded power supply, BNC shorting
plug (009 146), and operating instructions |
Combination pH electrode has a built in
reference electrode.
combination pH electrode = (Reference Electrode +
Measuring electrode) in one body |
Accessories
|
924 005 |
Glass bodied combination electrode |
|
027 113 |
Conductivity cell with ATC, glass K=0.1 |
|
027 177 |
Conductivity cell with ATC, glass K=1, flow-through |
|
027 211 |
Conductivity cell with ATC, epoxy K=0.1 |
|
027 212 |
Conductivity cell with ATC, epoxy K=1 |
|
027 213 |
Conductivity cell with ATC, epoxy K=10 |
|
027 013 |
Conductivity cell with ATC, glass K=1 |
|
027 500 |
ATC/temperature
probe |
|
025 179 |
pH 4
buffer sachets (ready to use( (pack 10) |
|
025 180 |
pH 7
buffer sachets (ready to use) (pack 10) |
|
025 181 |
pH
10 buffer sachets (ready to use) (pack 10) |
|
025 037 |
pH 4
colored buffer solution (red) (500ml) |
|
025 038 |
pH 7
colored buffer solution (yellow) (500ml) |
|
025 039 |
pH
10 colored buffer solution (blue) (500ml) |
|
025 162 |
pH
9.22 buffer solution (500ml) |
|
025 163 |
pH 2
buffer solution (500ml) |
|
025 160 |
3M
KCl electrode fill solution |
|
025 161 |
pH
electrode cleaning solution (pH) |
|
025 192 |
pH
electrode storage solution |
|
025 157 |
Redox standard (200mV) (500ml) |
|
025 158 |
Redox standard (300mV) (500ml) |
|
025 159 |
Redox standard (465mV) (500ml) |
|
025 139 |
Conductivity calibration standard 10µS (500ml) |
|
025 164 |
Conductivity calibration standard 84µS (500ml) |
|
025 138 |
Conductivity calibration standard 1413µS (500ml) |
|
025 156 |
Conductivity calibration standard 12.88mS (500ml) |
|
025 265 |
TDS
calibration standard 1382ppm (500ml) |
|
037 701 |
Thermal printer supplied with roll of paper and universal power
adapter |
|
037 702 |
Paper roll for thermal printer |
|
037 801 |
9
way serial cable |
|
037 901 |
Bench stirrer (battery operated) |
|
903 300 |
Electrode stand and holder |
|
903 311 |
Extended length electrode rod for 903 300 (recommended for use
with the battery stirrer) |
|
060 406 |
Dust
cover |
|
021 030 |
UK
230V power supply |
|
021 031 |
European 230V power supply |
|
021 032 |
US
115V power supply |
|
021 033 |
230V
leaded power supply |
|
050 501 |
DataWay Software on CD-ROM
includes electrochemistry interface cable (013 203) & spectrophotometer
interface cable (013 210) |

Home | Electrochemistry
Products | Online
Store | News
Contact Us | About
Us | Distributors
Copyright © 2008 Techne® Incorporated |